Honeywell DR4300 Circular Chart Recorder
What is it
The DR4500 circular chart recorder is a microprocessor-based recorder suitable to meet a wide range of industry requirements. It comes with a digital display and easy-to-use operator interface, and is available in many models to cater to the specific needs of different applications such as flow and HTST dairy processes. The Truline pen provides a convenient method to document a process while minimizing maintenance hassles. An integral PID controller and RS-485 Modbus communications ensure user empowerment. This accurate and easily configurable recorder is designed to work in tough industrial situations.
How does it work
Honeywell Truline circular chart recorders accept directly connected process signals which allow them to process data and create the chart under actual environmental conditions, eliminating the risk of temperature and humidity expansion of the paper and enhancing its accuracy. The chart recorders use single or dual pens or a hot-stylus type pen to produce the chart image. The simple design of these chart recorders makes them easy to operate even by inexperienced operators, and the modular construction makes them easy to maintain, modify and service. The bright, digital display and a dedicated configuration keypad bring further convenience to the user. These chart recorders come with NEMA 3 or NEMA 4 front face protection, making them suitable for tough production environments.
What problems does it solve
The DR4500 circular chart recorder eliminates the need to purchase individual circular charts for each application with its single circular chart requirement, thereby enabling cost savings to the user through reduced stocking of multiple circular charts.
Condition:
Used-was removed from working environment. Unit is in great condition with minor cosmetic wear from normal use.
System consists of:
Items as shown
Power cord
Specifications:
CONDITION : SPECIFICATION
Ambient Temperature: 32 to 131F (0 to 55C)
Relative Humidity: 5 to 90% RH at 40C (104F)
Vibration; Frequency ; Acceleration: 0 to 200 Hz / 0.2g
Mechanical Shock Acceleration ; Duration: 5g / 30 ms
Power: 102 to 132 Vac 50/60 Hz ; 204 to 264 Vac 50/60 Hz
Power Consumption: 20 watts maximum
Digital Indication Accuracy: 1 digit
Minimum Input Span: Range is fully configurable with span limitation of the operating range selected.
Input Impedance: 4-20 mA dc: 250 ohms ;0-10 Vdc: 200K ohms ; All others: 10 Megohms
Source Impedance: RTD: 100 ohms per lead maximum
Span Step Response Time: 6 seconds maximum with no filtering
Sampling Rate: Each input sampled 3 times a second
Input Filter: Software: Single pole low pass section with selectable time constants (off to 120
seconds).
Digital Displays: Vacuum fluorescent, alphanumeric. A six digit display dedicated to the process variable. Alternate information displayed during configuration mode. An eight digit display shows key selected operating parameters. Also provides guidance during configuration.
Indicators: Channel PV display (CHN 1 or 2) ; Alarm status (ALM 1, 2) ; Controller Output (OUT 1, 2) ; Remote Setpoint (RSP) ; Temperature unit (F or C) or Engineering Units ; Controllers mode (A or MAN)
Deviation Bargraph: 21 segment, color coded deviation bargraph: Green (large) = On Control Green (small) = Deviation to 10% of PV
Controller Modes of Operation: Manual Operation ; Automatic with local setpoint ; Automatic with remote setpoint
For equipment and items shipping via freight, please contact us with your zip code to obtain shipping quote.
Please do not hesitate to contact us if you have any questions.